You have reached the Request for Quote (RFQ) page for part number 11570, an item sourced from Sora Power Inc (CAGE Code 55196) that is classified with the item name Transformer Power. Here, you can utilize our online form to quickly secure tailored pricing and procurement options from our staff as the first step of procurement. With responses always being quick, be sure to get started as soon as possible if you would like to learn more about this part number.
The part number 11570 is associated with Sora Power Inc, identified by the CAGE Code 55196, and is typically referenced under the item name Transformer Power. It is categorized under the NSN 5950-00-324-0267, with the NIIN 003240267, INC 32496, and NCB code 00 (USA). Additionally, this part falls under the Federal Supply Group (FSG) 59 and Federal Supply Class (FSC) 5950 Coils and Transformers. For more information, these classifications provide further context about the component.
With the form provided, be sure to present our staff with key details on your needs, such as your target pricing, required quantity, and expected turnaround time. Once we receive and review your request for part 11570, a member of our staff will contact you in 15 minutes or less to present customized solutions for your comparisons. Once you make a purchase with us, you can expect our staff to work closely with you through each step of fulfillment to ensure that all needs are met with care and efficiency.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-324-0267 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003240267 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 984717-2B | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
| ABTB | MOUNTING HOLE DIAMETER | 0.380 INCHES NOMINAL SINGLE GROUP0.380 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 15.0 KILOHERTZ NOMINAL SINGLE COMPONENT15.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ADAU | BODY HEIGHT | 1.780 INCHES MAXIMUM1.780 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| FEAT | SPECIAL FEATURES | THIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST OF ONE PRIMARY AND SEVEN SECONDARY WINDINGSTHIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST O |
| PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
| TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB,SOLDER LUG |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote