When you would like to secure affordable procurement options for Sensata Technologies Maryland Inc part number APGN6-1REC4-23398-4, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Sensata Technologies Maryland Inc part number APGN6-1REC4-23398-4 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-394-8253 Item Description: Circuit Breaker | 5925 | 013948253 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| Apgn6-1rec4-23398-4 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | Body Style | SINGLE POLE TYPE |
| CSSX | Switch Current Rating And Type In Amps | 10.0 AC |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SINGLE LOCATION |
| ABXD | Bushing Length | 0.625 INCHES NOMINAL |
| FREQ | Frequency In Hertz | 47.5 SINGLE LOCATION OR 63.0 SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
| CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
| AKPX | Pole Quantity | 1 |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| ADAT | Body Width | 0.750 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
| ADTV | Case Material | METAL |
| CPRW | Actuator Function | TRIP-RESET |
| CPRX | Actuator Position Designation | AT POLE ONE |
| CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC |
| AJWX | Mounting Surface To Terminal End Distance | 2.232 INCHES MAXIMUM |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| ADAQ | Body Length | 2.000 INCHES NOMINAL |
| CQJX | Nominal Thread Size | 0.500 INCHES |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.530 INCHES NOMINAL |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CRTK | Switch Terminal Type | SCREW |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| MRC | Decoded Requirement | Clear Text Reply |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| THSD | Thread Series Designator | UNC |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!