When you would like to secure affordable procurement options for Schneider Electric Ltd part number BK400I, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Schneider Electric Ltd part number BK400I for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-465-1969 Item PartTypeName: POWER SUPPLY | 6130 | 014651969 | N | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 7 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| T1891102 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| APTS | OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | LIMITING CURRENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| ABKW | OVERALL HEIGHT | 150.0 MILLIMETERS NOMINAL |
| CWHF | OUTPUT CONNECTION QUANTITY | 4 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CBBL | FEATURES PROVIDED | BATTERY CHARGER AND CALIBRATED OUTPUT SIGNAL AND CIRCUIT BREAKER AND CIRCUIT OVERLOAD PROTECTION DEVICE AND EMI FILTER AND INPUT VOLTAGE RANGE SWITCH AND OVER CURRENT PROTECTOR AND VOLTAGE ADJUSTMENT |
| CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
| CWHY | BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
| AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 30.0 DEG CELSIUS |
| CWJF | BATTERY LOCATION | INTERNAL |
| BGHY | OUTPUT CONTROL TYPE | CURRENT LIMIT AND VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| APNX | INPUT VOLTAGE RATING | 240.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| ABHP | OVERALL LENGTH | 330.0 MILLIMETERS NOMINAL |
| BGQR | OUTPUT WATTAGE RATING | 300.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| CWWB | BATTERY RECOVERY TIME | 300.0 |
| ANRQ | FREQUENCY REGULATION PERCENT | 0.5 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| AMQY | INSTALLATION DESIGN | BENCH |
| CXNJ | POWER SUPPLIES PROGRAMMED PER SYSTEM | 4 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS |
| FEAT | SPECIAL FEATURES | INPUT VOLTAGE ADJUSTABLE IN FIVE INCREMENTS FROM A HIGH OF 220.0 TO 240.0 VAC, GREATER THAN 196.0 VAC, GREATER THAN 184.0 VAC, GREATER THAN 172.0 VAC, TO A LOW OF 160.0 VAC TO COMPENSA TE FOR BROWNOUT CONDITIONS; INPUT LINEUSES AN IEC 320 MALE APPLIANCE COUPLER; OPTION SWITCHES ALLOW FOR CUSTOMIZATION OF TRANSFER VOLTAGE (ON BATTERY) IN A STEPPED APPROXIMATION TO SINE WAVE AT 225.0 VAC PLUS OR MINUS 5 PERCENT, SET ALARM, AND CONTROL OUTPUT FREQUENCY SETTINGS; UNIT HAS 4 IEC FEMALE APPLIANCE COUPLERS; AMBIENT OPERATING HUMIDITY PLUS 0.0 TO 95.0 PERCENT (NON-CONDENSING); HOT SWAPPABLE USER-REPLACEABLE BATTERIES; WEIGHS 7.0 KG; LOW VOLTAGE DIRECTIVE 73/23/EEC, GS LICENSES BY VDE PER STANDARD EN60950 AND EN50091; EMC DIRECTIVE 89/336/EEC, C-TICK APPROVED, EN5022 (CISPR22) AND EN50082-1 |
| ABMK | OVERALL WIDTH | 90.0 MILLIMETERS NOMINAL |
| CWGH | OUTPUT CURRENT RATING | 500.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWGN | OUTPUT PHASE | SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| APPA | OUTPUT VOLTAGE RATING | 225.00 AC VOLTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!
Request for Quote