When you would like to secure affordable procurement options for Heinemann Electric Co Inc part number CD3-C3-DU-60-240-1, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Heinemann Electric Co Inc part number CD3-C3-DU-60-240-1 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-592-9196 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015929196 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | A | 0 | |||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| CD3-C3-DU-60-240-1 | 5 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 60.0 AMPERES AC ALL LOCATIONS |
| AJEC | Boss Height | 0.219 INCHES NOMINAL |
| AKPX | Pole Quantity | 3 |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRQ | Reset Method | MANUAL |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
| CPRR | Main Contact Tripping Mechanism Type | NONTRIP FREE |
| CPRW | Actuator Function | TRIP-RESET |
| CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
| ADAT | Body Width | 3.138 INCHES MAXIMUM |
| THSD | Thread Series Designator | UNC |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| TTQY | Terminal Type And Quantity | 4 SCREW |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| AJWX | Mounting Surface To Terminal End Distance | 3.485 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| ADAQ | Body Length | 5.125 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 3.547 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 35.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 ALL LOCATIONS |
| CPRX | Actuator Position Designation | AT POLE ONE AND AT POLE TWO AND AT POLE THREE |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!