When you would like to secure affordable procurement options for Eaton Corporation part number JE1S-T38-AA-11-D-A-10-251, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Eaton Corporation part number JE1S-T38-AA-11-D-A-10-251 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-351-5542 Item Description: Circuit Breaker | 5925 | 013515542 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| Je1s-T38-Aa-11-D-A-10-251 | 5 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.375 INCHES NOMINAL |
| THSD | Thread Series Designator | UNEF |
| AAQL | Body Style | SINGLE POLE TYPE |
| CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE AND MOISTURE RESISTANT |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| PKWT | Unpackaged Unit Weight | 2.500 OUNCES |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| BBRJ | Special Handling Feature | MAGNETIC |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION AND 65.0 DC SINGLE LOCATION |
| FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION AND 1000.0 DC SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| AKPX | Pole Quantity | 1 |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 SINGLE LOCATION |
| ADAT | Body Width | 0.750 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| CPRX | Actuator Position Designation | AT POLE ONE |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| AJWX | Mounting Surface To Terminal End Distance | 2.125 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| CQJX | Nominal Thread Size | 0.375 INCHES |
| ADAQ | Body Length | 2.000 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.560 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC SINGLE LOCATION AND 10.0 AMPERES DC SINGLE LOCATION |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CMLP | Thread Quantity Per Inch | 52 |
| CPRW | Actuator Function | TRIP-RESET |
![]() |
AS9120B and ISO 9001:2015 |
![]() |