When you would like to secure affordable procurement options for Eaton Corp Aerospace part number GH3Z3031, do not hesitate to take advantage of the Request for Quote (RFQ) form on this page. As you complete this form, be sure to offer us important details like your target price and expected fulfillment timeframe, as well as information for contacting you with our response. Within 15 minutes of receiving and reviewing your submission, a member of our staff will reach out to you to present a tailored solution on Eaton Corp Aerospace part number GH3Z3031 for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-552-4945 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015524945 | P | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| GH3Z3031 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CQQC | Trip Release Duty Cycle | INTERMITTENT ALL LOCATIONS |
| ABTD | Mounting Slot Width | 0.203 INCHES NOMINAL |
| AKPX | Pole Quantity | 3 |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 480.0 AC ALL LOCATIONS |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.375 INCHES NOMINAL |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
| AJEC | Boss Height | 0.250 INCHES NOMINAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRQ | Reset Method | MANUAL |
| AXHR | Mounting Facility Type And Quantity | 4 SLOT |
| CPSM | Internal Trip Release Configuration | SERIES/RELAY TRIP ALL LOCATIONS |
| ADTV | Case Material | PLASTIC |
| ADAT | Body Width | 4.125 INCHES NOMINAL |
| FEAT | Special Features | 2 ELECTRICALLY ISOLATED COILS; COIL NUMBER 1 TIME DELAY; COIL NUMBER 2 INSTANTANEOUSLY TRIPPED BY CURRENT(220.0 VOLTS, 50.0 TO 60.0 HERTZ, 30.0 VA), SUPPLIED BY CONTROL EQUIPMENT OR REMOTE MONITORING SYSTEM; ULTIMATE TRIP RATING FOR COIL 2 IS 120.0 PERCENT |
| AJWX | Mounting Surface To Terminal End Distance | 3.125 INCHES NOMINAL |
| MRC | Decoded Requirement | Clear Text Reply |
| ADAQ | Body Length | 6.000 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 5.000 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CPRK | Auxiliary Trip Coil Voltage Type And Rating In Volts | 220.0 AC NOMINAL ALL LOCATIONS |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 4.687 INCHES NOMINAL |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
OVER 75000
Same-day
COMPLETE PURCHASING
FULLY CERTIFIED
COMPETITIVEBefore You Go, Take a Look at Our NSN Parts Catalog! Don’t forget That We Can offer A Competitive Quote Within 15 Minutes of Receiving Your RFQ form!